Saturday, October 20, 2018

a52_dtul imei repair problem

  Unlock4samsung       Saturday, October 20, 2018
hi all moderators
I need to change imei for a52_dtul .

Reading information...
Using Fastboot mode...
Reading common information
(bootloader) version: 0.5
(bootloader) version-bootloader: 3.19.0.0000
(bootloader) version-baseband: 1.0.U20410.1@60201
(bootloader) version-cpld: None
(bootloader) version-microp: None
(bootloader) version-main: 2.10.401.3
(bootloader) version-misc: PVT SHIP S-ON
(bootloader) serialno: HT5CSYG00322
(bootloader) imei: 357290069024038
(bootloader) imei2: 357290069024046
(bootloader) meid: 00000000000000
(bootloader) product: a52_dtul
(bootloader) platform: hTCBmsm8939
(bootloader) modelid: 0PHC10000
(bootloader) cidnum: HTC__J15
(bootloader) battery-status: good
(bootloader) battery-voltage: 0mV
(bootloader) partition-layout: Generic
(bootloader) security: on
(bootloader) build-mode: SHIP
(bootloader) boot-mode: FASTBOOT
(bootloader) commitno-bootloader: 87c55d84
(bootloader) hbootpreupdate: 11
(bootloader) gencheckpt: 0
(bootloader) mfg-name: 1001
all: Done!
Execution time is 12(ms)
Reading CID information
... (bootloader) cid: HTC__J15
OKAY
Execution time is 4(ms)
Reading MEID information
... (bootloader) meid: 00000000000000
OKAY
Execution time is 5(ms)
Reading IMEI1 information
... (bootloader) imei: 357290069024038
OKAY
Execution time is 5(ms)
Reading IMEI2 information
... (bootloader) imei2: 357290069024046
OKAY
Execution time is 5(ms)
Reading secure flag information
... (bootloader) secure_flag: 3
OKAY
Execution time is 4(ms)
Reading serial number information
... (bootloader) [ERR] Command error !!!
OKAY
Execution time is 4(ms)
Reading color information
... (bootloader) [ERR] Command error !!!
OKAY
Execution time is 6(ms)
Read information completed.


Sending oem writesecureflag 0
... (bootloader) SecuritySDInit: counter = 7
(bootloader) a52dtul_init_sd, SD card already power on
(bootloader) a52dtul_init_sd, SD card io already power on
(bootloader) sdhci_open: id=0
(bootloader) Initializing MMC host data structure and clock!
(bootloader) mmc slot#2 clock enabled
(bootloader) sdhci_set_clock: slot 2, freq 192000000
(bootloader) GPLL0 is enabled
(bootloader) clock_update_cfg_sd is done
(bootloader) sd clock set done
(bootloader) sdhci_set_bus_width: bus width 0
(bootloader) sdhci_clk_supply: freq 400000
(bootloader) Error: Command never completed
(bootloader) Error: Command timeout error
(bootloader) Error: Command completed with errors
(bootloader) The response for CMD8 does not match the supplied value
(bootloader) Decoded CID fields:
(bootloader) Manufacturer ID: 7f
(bootloader) OEM ID: 0x0
(bootloader) Product Name: 5270
(bootloader) Product revision: 5.2
(bootloader) Product serial number: B4E
(bootloader) Manufacturing date: 2 2015
(bootloader) sdhci_clk_supply: freq 50000000
(bootloader) sdhci_set_bus_width: bus width 1
(bootloader) Done initialization of the card
(bootloader) erase_grpsize: 1773420032
(bootloader) erase_grpmult: 49152
(bootloader) wp_grpsize: 1
(bootloader) wp_grpen: 1
(bootloader) perm_wp: 0
(bootloader) temp_wp: 0
(bootloader) [SD_ERR] sd_read_sector: read sector failed (778135908 1)
(bootloader) [Tuxera][Error] Primary partition 0 (778135908/1141509631):
(bootloader) failed to read sector #778135908
(bootloader) [SD_ERR] sd_read_sector: read sector failed
Operation finished
logoblog